Basic Info.
Specification
ce, ce, sgs
Product Description
Place of Origin: Zhejiang, China (Mainland)
Brand Name:CNSCKJ
Model Number: PM-D2
Display Type: Digital Only
Phase: Single Phase
Measuring Energy Range: 0-9999
Accuracy Class: 0.5
Output Voltage: 0-9999
Operating Temperature: -10ºC~+55ºC
Dimensions: panel size 120*120
Wiring of multifunction meter: single-phase
Rated current of multifunction meter: AC 1A,AC 5A
Rated voltage of multifunction meter: AC 57.7V,AC 100V,AC 220V,AC 380V
Accuracy of multifunction meter: 0.2/0.5/1.0/2.0
Frequency of multifunction meter: 45~65Hz
Impedance of multifunction meter: Voltage: >300KΩ , Current: <20mΩ
Working range of multifunction meter: AC/DC 80V~270V
Storage environment of meter: -25ºC~ +70ºC
Relative humidity of multifunction meter: ≤93 %,in the place without corrosive gas
Height above sea level of meter: ≤2500m
Packaging
Selling Units: | Single item |
---|
Single package size: | 17X14X17 CM |
---|
Single gross weight: | 0.594 KG |
---|
Feature |
?Measure single phase voltage, signle phase current, active power, reactive power, apparent power, power factor and frequency with high-precision. |
?Measure forward and reverse active/reactive energy. |
?Measure and timing read time of use energy. |
?Measure total harmonic distortion (THD) and 2-31times odd harmonic components of single phase voltage and single phase current. |
?Provide LED display and local data query. |
?Visual menus, buttons easy to operate. |
?Programmable current and voltage transformation ratio. |
?Provide multiloop leakage current monitoring |
?Provide multiloop control nodes for alarm and trip control |
?Support the fire alarm and control to cut off power supply of failure point remotely |
?Support RS-485 communications and Modbus-RTU protocol. |
?Supportdigital input, digital output, analog transmission output and energy pulse output. |
?Easy installation, simple wiring, small quantities. |
?Wide range of AC/DC universal power supply: AC / DC 80V~270V |
?Can complete a variety of communication software network in SCADA and PLC. |
Technical Index |
Accuracy Measurement |
current | class 0.5 |
Voltage | class 0.5 |
active power | class 0.5 |
reactive power | class 0.5 |
power factor | class 0.5 |
frequency | ±0. 02Hz |
active Energy | class 0.5/class 0.2 |
reactive Energy | class 1.0/class 2.0 |
Input Measurement |
Wiring | single-phase |
Rated current | AC 1A,AC 5A |
Rated voltage | AC 57.7V,AC 100V,AC 220V,AC 380V |
Overload | Voltage:Sustained:1.2times;Instantaneous:2times/1s |
Current:Sustained: 1.2 times; Instantaneous: 10 times/ 5s |
Power consumption | Voltage: <1VA (per phase),Current: <0.4VA (per phase) |
Impedance | Voltage: >300KΩ , Current: <20mΩ |
Frequency | 45~65Hz |
Power supply |
Working range | AC/DC 80V~270V |
Power consumption | <4VA |
Functional Module |
Communication interface | 1 loop RS-485 Communication, MODBUS-RTU protocol |
Baud rate: 2400 ~ 19200bps, Default: 2400bps |
Switching value input | 4 loops switching value input, dry joint |
Switching value output | 3 loops relay output, capability: AC 250V/5A,DC 30V/5A |
Transmission output | 1 loops analog output: 0/4~20 mA or 0~5/10 V |
Energy pulse output | 2 loops energy pulse output, constant: 8000 |
Environment |
Operational environment | -10ºC~+55ºC |
Storage environment | -25ºC~ +70ºC |
Relative humidity | ≤93 %,in the place without corrosive gas |
Height above sea level | ≤2500m |
Safety |
Insulation resistance | > 100MΩ |
AC withstand voltage | AC 2KV |
Electro Magnetic Compatibility |
Electro-Static discharge | class 4 |
Electrical Fast Transient pulse train | class 4 |
Electrical surge | class 4 |
Outline Dimension |
External Dimension( mm ) | 120×120;80×80;96×48;96×96;72×72;48×48;120x60;160x80 |
Cutout Dimension( mm ) | 111×111;76×76;92×45;92×92;68×68;45×45;114x56;152x76 |
Specification Matching |
Model Function | Measurement | Extended Function(Optional) | Display | Cutout Dimension ( mm ) | External Dimension ( mm ) |
single-phase electric parameters | Switch input | Switch output | Transmission output | Communication interface | LED | LCD |
PM-D1 | √ | 2 | 2 | 1 | 1 | √ | - | 152X76 | 160x80 |
PM-D1Y | √ | 2 | 2 | 3 | 1 | - | √ |
PM-D2 | √ | 2 | 2 | 3 | 1 | √ | - | 111X111 | 120×120 |
PM-D2Y | √ | 2 | 2 | 3 | 1 | - | √ |
PM-D3 | √ | 2 | 2 | 3 | 1 | √ | - | 92X92 | 96×96 |
PM-D3Y | √ | 2 | 2 | 1 | 1 | - | √ |
PM-D4 | √ | 2 | 2 | 1 | 1 | √ | - | 114X56 | 120x60 |
PM-D4Y | √ | 2 | 2 | 1 | 1 | - | √ |
PM-D5 | √ | 2 | 2 | 1 | 1 | √ | - | 92X45 | 96×48 |
PM-D5Y | √ | 2 | 2 | 1 | 1 | - | √ |
PM-D6 | √ | 2 | 2 | 1 | 1 | √ | - | 68X68 | 72×72 |
PM-D6Y | √ | 2 | 2 | 1 | 1 | - | √ |
PM-D7 | √ | 2 | 2 | 1 | 1 | √ | - | 76×76 | 80×80 |
PM-D7Y | √ | 2 | 2 | 1 | 1 | - | √ |
PM-D8 | √ | 2 | 2 | 1 | 1 | √ | - | 45×45 | 48×48 |
Model Function | Measurement | Extended Function(Optional) | Display | Cutout Dimension ( mm ) | External Dimension ( mm ) |
3-phase electric parameters | Multi-rate | Harmonic | Fire monitoring | Switch input | Switch output | Transmission output | Communication interface | LED | LCD |
PM-3D2 | √ | - | - | - | 4 | 4 | 4 | 2 | √ | - | 111X111 | 120x120 |
PM-3D2Y | √ | - | - | - | 4 | 4 | 4 | 2 | - | √ |
PM-3FD2Y | √ | √ | - | - | 4 | 4 | 4 | 2 | - | √ |
PM-3HD2Y | √ | - | √ | - | 4 | 4 | 4 | 2 | - | √ |
PM-3LD2 | √ | - | - | √ | 4 | - | - | 2 | √ | - |
PM-3LD2Y | √ | - | - | √ | 4 | - | - | 2 | - | √ |
PM-3FHD2Y | √ | √ | √ | - | 4 | 4 | 4 | 2 | - | √ |
PM-3D3 | √ | - | - | - | 4 | 4 | 4 | 2 | √ | - | 92X92 | 96×96 |
PM-3D3Y | √ | - | - | - | 4 | 4 | 4 | 2 | - | √ |
PM-3FD3Y | √ | √ | - | - | 4 | 4 | 4 | 2 | - | √ |
PM-3HD3Y | √ | - | √ | - | 4 | 4 | 4 | 2 | - | √ |
PM-3LD3 | √ | - | - | √ | 4 | - | - | 2 | √ | - |
PM-3LD3Y | √ | - | - | √ | 4 | - | - | 2 | - | √ |
PM-3FHD3Y | √ | √ | √ | - | 4 | 4 | 4 | 2 | - | √ |
PM-3D7 | √ | - | - | - | - | - | - | 1 | √ | - | 76×76 | 80×80 |
PM-3D7Y | √ | - | - | - | - | - | - | 1 | - | √ |
PM-3D6 | √ | - | - | - | - | - | - | 1 | √ | - | 68X68 | 72×72 |
PM-3D6Y | √ | - | - | - | - | - | - | 1 | - | √ |
PM-3D8 | √ | - | - | - | - | - | - | 1 | √ | - | 45×45 | 48×48 |
Note: The number of optional extended functions would be the maximum number we can extend in normal conditions. If you have any special request, please contact with our technical department. |
Address:
No. 358 Liujiang Road, Liushi Town, Yueqing City, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Instruments & Meters
Company Introduction:
Wenzhou CNSCKJ Meter Technology Co., Ltd. Specialized in manufacturing various digital display meter, which is member enterprise of the National Electrician instrument& Meter Standardization Committee. The products manufactured by our company strictly complied with IEC 51 publication rev4 issued by international electrician Committee and IEC1010 Standard, and meet the National Standard Requirement GB/T7676-1998. CNSCKJ company have passed through ISO9001: 2000 Certificate and CE Certificate.
(1) We are one of organizations chiefly editing the national standard, Mounted Digital Display Electric Measuring Instrument:
(2)We are involved in the edition of national standards, low-voltage Reactive Power Compensation Switching Device and General Specification for Digital Motor Combined Protection Equipment;
(3)We participate in the revision work of industrial standard, low -voltagea Reactive Power Compensation Control Device
(4) We play an essential role in editing the national standard diagram collections for electrical design, commonly-used Pump Control Circuit Diagram and Commonly-USD Blower Control Circuit Diagram, and the reference diagram collections for eletrical design, Fire-fighting Equipment Power Supply Monitoring System.
Under holding up the enterprise tenet: Survive on quality, Create brand with the credit, CNSCKJ sincerely wish friends at home and abroad to cooperate with for brilliant tomorrow!